Comparación del trasporte del conducto y capacidad de centrado con Protaper Next y Waveone. (Registro nro. 8081)

000 -CABECERA
Campo de control de longitud fija 04735nam a22002537a 4500
003 - IDENTIFICADOR DEL NÚMERO DE CONTROL
Campo de control OSt
005 - FECHA Y HORA DE LA ÚLTIMA TRANSACCIÓN
Campo de control 20180919094526.0
008 - CÓDIGOS DE INFORMACIÓN DE LONGITUD FIJA
Campo de control de longitud fija 160126b xxu||||| |||| 00| 0 eng d
040 ## - FUENTE DE LA CATALOGACIÓN
Centro catalogador de origen Unicoc
Lengua de catalogación spa
Centro transcriptor Unicoc
082 ## - NÚMERO DE LA CLASIFICACIÓN DECIMAL DEWEY
Número de clasificación T.O.E. 0086
100 ## - PUNTO DE ACCESO PRINCIPAL - NOMBRE DE PERSONA
9 (RLIN) 3373
Nombre de persona Bacca Ramírez, Diana Fernanda
245 ## - MENCIÓN DE TÍTULO
Título Comparación del trasporte del conducto y capacidad de centrado con Protaper Next y Waveone.
Mención de responsabilidad etc. Diana Bacca, Xiomara Gomez, Oriana Valenti
260 ## - PUBLICATION, DISTRIBUTION, ETC. (IMPRINT)
Lugar de publicación distribución etc. Bogotá (Colombia);
Nombre del editor distribuidor etc. Institución Universitaria Colegios de Colombia -Unicoc-:
Fecha de publicación distribución etc. 2015.
500 ## - NOTA GENERAL
Nota general Incluye Tabla de Contenido y Referencias Bibliográficas.
504 ## - NOTA DE BIBLIOGRAFÍA; ETC.
Nota de bibliografía etc. A. Científico: Patricia Paredes Paredes ; A. Metodológico: Diana Parra .
505 ## - NOTA DE CONTENIDO CON FORMATO
Nota de contenido con formato
Título RESUMEN
Objetivo: Determinar el transporte del conducto y capacidad de centrado del sistema de limas ProTaper Next y Wave One en conductos radiculares observados con tomografía computarizada (CBTC). Métodos: Estudio experimental observacional in vitro en 40 premolares decoronados, a los cuales se les tomó CBCT inicial para observar la anatomía original del conducto y foramen apical. Las muestras fueron divididas en dos grupos: 1er Grupo: 20 se prepararon con el sistema ProTaper Next lima X1 y X2. 2do Grupo: 20 con el sistema Wave One lima Primary. Después se les tomó una segunda CBCT para evaluar la posición del conducto y foramen apical luego de la instrumentación. Resultados: Al analizar los datos de los cambios en la ubicación de los conductos antes y después de la preparación con los sistemas ProTaper Next y Wave One, no existen diferencias estadísticas significativas (p>0.05). El valor más alto se observa en los cortes a 8 mm donde hubo un transporte del conducto de 0.75 con Wave One. En los cortes a 4 mm se observó que Protaper Next produjo mayor transporte del conducto; y en el foramen apical (0mm) menor que Wave one. Conclusión: La creación de un preensanchamiento en el tercio coronal con oriffice opener proporciona una entrada más segura y directa hacia el tercio apical, reduce fricción con las paredes radiculares, aumento eficacia de irrigantes, mejor conformación y obturación. El uso de las limas Wave one Primary tienden a desgastar más estructura dental, su uso debe ser limitado en conductos estrechos. Las propiedades metalúrgicas, diseño del instrumento y forma de uso son variables más significativas en el transporte del conducto durante la instrumentación que el tipo de movimiento.
505 ## - NOTA DE CONTENIDO CON FORMATO
Nota de contenido con formato
Título SUMMARY
Objective: determine the capacity transport and centering of the canal with ProTaper Next and Wave One files in root canals observed with computerized tomography (CBTC). Methods: study experimental observational in vitro in 40 premolars, to which they were taken CBCT Initial to see the original canal anatomy and apical foramen. The samples were divided into two groups: 1st group: 20 were prepared with ProTaper Next lima X1 and X2 system. The 2nd Group 20 with Primary Wave One file system. After they took a second CBCT to assess the position of the canal and apical foramen after instrumentation. Results: When analyzing the data of changes in the location of the canal before and after preparation with ProTaper Next and Wave One systems, there are no statistically significant differences (p> 0.05). The highest value observed in cuts 8 mm where there was a transport canal with 0.75 Wave One In sections to 4 mm was observed that produced greater ProTaper Next transport canal; and the apical foramen (0mm) less than Wave one. Conclusion: Creating a preensanchament in the coronal third with oriffice opener provides a safer and towards the apical third entry, reduce friction with the root walls, irrigating increase efficiency, better conformation and sealing. The use of Primary files Wave one tend to wear more tooth structure, its use should be limited in narrow passages. Metallurgical properties, design and method of use instrument influence the transport canal during instrumentation. Centricity canal and apical foramen were not affected by type of movement ProTaper Next (continuous rotation) and Wave One (reciprocating).
505 ## - NOTA DE CONTENIDO CON FORMATO
Nota de contenido con formato
Título Palabras clave: Centricidad del conducto, Transporte apical, ProTaper Next, Wave One. ; - Keywords: centricity canal, apical Transportation, ProTaper Next, Wave One
650 #0 - PUNTO DE ACCESO ADICIONAL DE MATERIA - TÉRMINO DE MATERIA
9 (RLIN) 403
Término de materia o nombre geográfico como elemento inicial Odontología / Endodoncia - Tesis y disertaciones academicas.
700 ## - PUNTO DE ACCESO ADICIONAL - NOMBRE DE PERSONA
9 (RLIN) 4316
Nombre de persona Gomez Arleo, Xiomara Alexandra
700 ## - PUNTO DE ACCESO ADICIONAL - NOMBRE DE PERSONA
9 (RLIN) 4317
Nombre de persona Valenti Yodice, Oriana
773 ## - ENLACE AL DOCUMENTO FUENTE
Lugar editor y fecha de publicación Bogotá (Colombia), Institución Universitaria Colegios de Colombia -Unicoc-, 2015.
Título Comparación del trasporte del conducto y capacidad de centrado con Protaper Next y Waveone.
Número Internacional Normalizado para Publicaciones Seriadas (ISSN) T.O.E. 0086
942 ## - ENTRADA PARA ELEMENTOS AGREGADOS (KOHA)
Fuente de clasificación o esquema de ordenación en estanterías
Koha [por defecto] tipo de item Trabajo de Grado
Existencias
Localización actual Estado de pérdida Fuente de clasificación o esquema de ordenación en estanterías Préstamos totales Signatura completa Fecha último préstamo Fecha del precio de reemplazo Número de ejemplar Fecha de adquisición Estropeado No para préstamo Fecha última consulta Tipo de item de Koha Número de inventario Localización permanente Código de barras
Biblioteca Cali (Dr. Jairo Forero Morales)   T.O.E. 0086 2016-02-09Ejemplar 12016-02-09  2016-02-09Trabajo de Grado Biblioteca Cali (Dr. Jairo Forero Morales)3676
Biblioteca Cali (Dr. Jairo Forero Morales)   TBA T.O.E. 0086 2016-02-09Ejemplar 12016-02-09  2016-02-09Trabajo de Grado Biblioteca Cali (Dr. Jairo Forero Morales)3677
Bogotá (Dr. David Ordóñez Rueda) - Campus Norte  2T.O.E. 00862016-04-262016-01-26Ejemplar 12015-12-18  2016-04-26Trabajo de Grado2 Tesis; 2 Articulos;2CD´sBogotá (Dr. David Ordóñez Rueda) - Campus Norte20152E0086

© 2014 UNICOC | Institución Universitaria Colegios de Colombia - UNICOC
Bogotá D.C. Autopista Norte Km. 20. Teléfono:(571)6683535
Cali: Calle 13 Norte No. 3N-13. Teléfono: (572)6608887

Idiomas: 
Con tecnología de Koha