245 _aEficacia de la Terapia de Desensibilización Dental con técnica Láser de Diodo 940 Nm Vs Desensibilización Tópica con Nitrato de Potasio Al 5 % : Un Ensayo Clínico Aleatorizado.
_cXimena Alexandra Espitia Robayo.
260 _aBogotá (Colombia);
_bInstitución Universitaria Colegios de Colombia - UNICOC,
_c2017.
300 _e2 cd
500 _aIncluye tabla de contenido y referencias bibliográficas.
504 _aAsesor científico: Dr. Oscar Ivan Tocarruncho, Asesor metodológico: Dra. Diana Parra, Asesor Estadístico: Dr. Gerardo Ardila.
505 _tRESUMEN Objetivo: Comparar la eficacia del tratamiento desensibilizante con láser de diodo 940nm vs Nitrato de Potasio 5%, en pacientes con sintomatología de hipersensibilidad dentinal después de una terapia periodontal. Materiales y métodos: Ensayo clínico aleatorizado que incluyó 30 pacientes en fase de mantenimiento periodontal y que presentaban recesiones gingivales (Miller 1985) clase I, II, III con sintomatología de hipersensibilidad dentinal. La muestra fue seleccionada aleatoriamente para formar los grupos del estudio. El primer grupo (n= 15) recibió la aplicación de láser de 940nm por 90 segundos sobre la superficie de la recesión, al mismo tiempo se le proporcionó a los pacientes un tubo de glicerina para ser aplicado diariamente para no generar sesgos, y a los pacientes del segundo grupo (n= 15) se les aplicó el láser inactivo simulando la aplicación real del mismo y se les proporcionó gel desensibilizante con contenido de nitrato de potasio 5 % , para que fuera aplicado diariamente 2 veces al día durante 14 días. Se realizaron controles a los 15 minutos, 8 días, 15 días y 4 semanas. Los datos obtenidos fueron diligenciados en una tabla de Excel. La investigación fue aprobada por el Comité de Ética y clasificada como riesgo mayor que el mínimo. Resultados: De los 30 pacientes hay una disminución en los niveles de Dhs comparando su sensibilidad inicial, y posterior a las intervenciones, presentando diferencias significativas en las dos intervenciones realizadas Conclusiones: Se encontró que las dos terapias láser y nitrato de potasio son eficaces para el manejo de la hipersensibilidad dentinal post tratamiento periodontal observándose una diferencia significativa en la disminución de la sensibilidad con la terapia láser.
505 _tABSTRACT Objective: to compare the effectiveness of treatment with the 940nm diastase vs Potassium Nitrate in patients with symptoms of dental hypersensitivity after periodontal therapy. Materials and Methods: This randomized clinical trial included 30 patients who were previously undergoing periodontal basic therapy and presented Class I and Class II gingival recession (Miller 1985) with symptoms of dentinal hypersensitivity. The sample was randomly selected to form the study groups. The first group (n = 15) received the laser application of 940nm for 90 seconds on the surface of the recession at the same time patients were given a tube of glycerine to be applied daily in order to avoid generate bias, and the patients in the second group (n = 15) were given the inactive laser simulating the actual application of the laser, and they were given a desensitizing gel containing 0.5g of potassium nitrate to be applied twice daily during 14 days. Controls were carried out at 15 minutes, 8 days, 15 days, and 4 weeks. Data obtained were filled out in an Excel table. The research was approved by the Ethics Committee and classified without risk. Results: Of the 30 patients there was a decrease in DHs levels comparing their initial sensitivity, and post-intervention, presenting significant differences in the two interventions performed. Conclusions: It was found that both laser and nitrate therapies are efficacious for the management of the post-periodontal dentinal hypersensitivity, observed was a significant difference in the dissolution of the sensitivity in laser therapy.
505 _tPalabras clave: láser diodo, sensibilidad dental, nitrato de potasio, enfermedad periodontal, recesiones gingivales.;- Key words: Diode laser, dentinal sensitivity, potassium nitrate, periodontal disease, gingival recession.
650 0 _9383
_aOdontología / Periodoncia - Tesis y Disertaciones Academicas
700 _96015
_aMarchena de Medina, Orlando Jose
700 _96016
_aRengifo Rincón, Ramiro
773 _dBogotá, Institución Universitaria Colegios de Colombia - UNICOC, 2017.
_tEficacia de la Terapia de Desensibilización Dental con técnica Láser de Diodo 940 Nm Vs Desensibilización Tópica con Nitrato de Potasio Al 5 % : Un Ensayo Clínico Aleatorizado.
_x20171TOPe0077
942 _2ddc
_cTESIS
999 _c8396
_d8396