000 -CABECERA | |
---|---|
Campo de control de longitud fija | 04205nam a22002537a 4500 |
003 - IDENTIFICADOR DEL NÚMERO DE CONTROL | |
Campo de control | OSt |
005 - FECHA Y HORA DE LA ÚLTIMA TRANSACCIÓN | |
Campo de control | 20180927111342.0 |
008 - CÓDIGOS DE INFORMACIÓN DE LONGITUD FIJA | |
Campo de control de longitud fija | 180308b xxu||||| |||| 00| 0 eng d |
040 ## - FUENTE DE LA CATALOGACIÓN | |
Centro catalogador de origen | Unicoc |
Lengua de catalogación | Spa |
Centro transcriptor | UNICOC |
082 ## - NÚMERO DE LA CLASIFICACIÓN DECIMAL DEWEY | |
Número de clasificación | T.O.Pe.080 |
100 ## - PUNTO DE ACCESO PRINCIPAL - NOMBRE DE PERSONA | |
9 (RLIN) | 6202 |
Nombre de persona | Gueto Molina, Claudia Lucia |
245 ## - MENCIÓN DE TÍTULO | |
Título | Alteraciones de las Superficies de los Implantes de Titanio posterior a la Irradiación con Laser de Diodo: In Vitro |
Mención de responsabilidad etc. | Narváez Solarte, Vanessa Alejandra;Ramírez Penagos, Angélica María. |
260 ## - PUBLICATION, DISTRIBUTION, ETC. (IMPRINT) | |
Lugar de publicación distribución etc. | Bogotá, D.C (Colombia) |
Nombre del editor distribuidor etc. | Institución Universitaria Colegios de Colombia- UNICOC |
Fecha de publicación distribución etc. | 2017 |
300 ## - DESCRIPCIÓN FÍSICA | |
Material anejo | 2 CD |
500 ## - NOTA GENERAL | |
Nota general | Incluye tabla de contenido y referencia bibliográfica |
504 ## - NOTA DE BIBLIOGRAFÍA; ETC. | |
Nota de bibliografía etc. | Asesor Científico: Dr. Fabio Andres Jimenez Castellanos; Directora Centro de Investigación: Sandra Elizabeth Aguilera Rojas; Asesora Metodológica: Dr. Camilo Novoa; Asesor Estadistico: Dr. Edgar Ibañez. |
505 ## - NOTA DE CONTENIDO CON FORMATO | |
Nota de contenido con formato | RESUMEN: Objetivo: Identificar los cambios en la topografía superficial (Ra) de los implantes dentales de titanio irradiados con láser diodo. Método: 10 implantes de titanio grado V con tratamiento de superficie de grabado acido fueron irradiados con láser diodo a diferentes potencias (1.60 W y 3.50 W), mientras que 3 implantes no recibieron ningún tipo de irradiación (grupo control). Las superficies de los implantes tratados fueron irradiadas durante 10 segundos, con la fibra en contacto con la superficie. Posteriormente las superficies de los implantes fueron analizadas por microscopio electrónico de barrido (SEM) y sistema EDS, donde se utilizaron magnificaciones de 250 µm y 700 µm. Resultados: El análisis por SEM demostró alteraciones en forma de rayón tanto en las superficies del grupo 1 irradiadas con una potencia de 1.60 W, así como las del grupo 2 irradiadas con una potencia de 3.50 W. Al evaluar la amplitud de las alteraciones entre los grupos no hubo diferencia significativa. En los especímenes del grupo control no se observaron alteraciones. Al análisis de la composición de los especímenes por el sistema EDS, no se encontraron diferencias significativas en los diferentes grupos. Conclusión: Al realizar irradiación con láser de diodo en implantes de titanio con grabado acido se presentaron alteraciones, sin embargo, las potencias utilizadas no influyeron en el tamaño, tipo de alteraciones y composición química superficial. |
505 ## - NOTA DE CONTENIDO CON FORMATO | |
Nota de contenido con formato | ABSTRACT: Objective: To identify changes in the surface topography (Ra) of titanium dental implants irradiated with laser diode. Method: 10 V-grade titanium implants with surface treatment of acid etching were irradiated with laser diode at different powers (1.60 W and 3.50 W), while 3 implants did not receive any type of irradiation (control group). The surfaces of the implants were irradiated for 10 seconds, with the fiber in contact with the surface. Subsequently the surfaces of the implants were analyzed by scanning electron microscopy (SEM) and EDS system, where magnifications of 250 μm and 700 μm are used. Results: The analysis by SEM showed alterations in the rayon shape on the surfaces of group 1 irradiated with a power of 1.60 W, as well as those of group 2 irradiated with a power of 3.50 W. When evaluating the amplitude of the alterations among the groups there was no significant difference In the specimens of the control group no alterations were observed. When analyzing the composition of the specimens by the EDS system, there are no significant differences in the different groups. Conclusion: When performing irradiation with diode laser in titanium implants with acid etching, alterations are presented, however, the potencies used did not influence the size, type of alterations and superficial chemical composition. |
650 #0 - PUNTO DE ACCESO ADICIONAL DE MATERIA - TÉRMINO DE MATERIA | |
9 (RLIN) | 392 |
Término de materia o nombre geográfico como elemento inicial | Odontología / Prostodoncia - Tesis y disertaciones académicas. |
700 ## - PUNTO DE ACCESO ADICIONAL - NOMBRE DE PERSONA | |
9 (RLIN) | 6203 |
Nombre de persona | Narváez Solarte, Vanessa Alejandra |
700 ## - PUNTO DE ACCESO ADICIONAL - NOMBRE DE PERSONA | |
9 (RLIN) | 6204 |
Nombre de persona | Ramírez Penagos, Angélica María |
773 ## - ENLACE AL DOCUMENTO FUENTE | |
Lugar editor y fecha de publicación | Bogotá, D.C Institución Universitaria Colegios de Colombia- UNICOC, 2017 |
Título | Alteraciones de las Superficies de los Implantes de Titanio posterior a la Irradiación con Laser de Diodo: In Vitro |
Número Internacional Normalizado para Publicaciones Seriadas (ISSN) | 20172TOPe080 |
942 ## - ENTRADA PARA ELEMENTOS AGREGADOS (KOHA) | |
Fuente de clasificación o esquema de ordenación en estanterías | |
Koha [por defecto] tipo de item | Trabajo de Grado |
Estado de pérdida | Fuente de clasificación o esquema de ordenación en estanterías | No para préstamo | Fecha última consulta | Estropeado | Localización permanente | Número de inventario | Número de ejemplar | Signatura completa | Fecha del precio de reemplazo | Localización actual | Fecha de adquisición | Tipo de item de Koha | Código de barras |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
2018-03-08 | Bogotá (Dr. David Ordóñez Rueda) - Campus Norte | 2 Tesis, 2 cd´s, 2 Articulos | Ej.1 | T.O.Pe.080 | 2018-03-08 | Bogotá (Dr. David Ordóñez Rueda) - Campus Norte | 2018-03-08 | Trabajo de Grado | 20172TOPe080 |
© 2014 UNICOC | Institución Universitaria Colegios de Colombia - UNICOC
Bogotá D.C. Autopista Norte Km. 20. Teléfono:(571)6683535
Cali: Calle 13 Norte No. 3N-13. Teléfono: (572)6608887