Deformación y límite de fractura de dos sistemas rotatorios (Protaper Universal y Protaper Next) Posterior al uso clínico. (Registro nro. 8080)

000 -CABECERA
Campo de control de longitud fija 03815nam a22002537a 4500
003 - IDENTIFICADOR DEL NÚMERO DE CONTROL
Campo de control OSt
005 - FECHA Y HORA DE LA ÚLTIMA TRANSACCIÓN
Campo de control 20180919094038.0
008 - CÓDIGOS DE INFORMACIÓN DE LONGITUD FIJA
Campo de control de longitud fija 160126b xxu||||| |||| 00| 0 eng d
040 ## - FUENTE DE LA CATALOGACIÓN
Centro catalogador de origen Unicoc
Lengua de catalogación spa
Centro transcriptor Unicoc
082 ## - NÚMERO DE LA CLASIFICACIÓN DECIMAL DEWEY
Número de clasificación T.O.E. 0085
100 ## - PUNTO DE ACCESO PRINCIPAL - NOMBRE DE PERSONA
9 (RLIN) 4313
Nombre de persona Muller Gomez, Elizabeth
245 ## - MENCIÓN DE TÍTULO
Título Deformación y límite de fractura de dos sistemas rotatorios (Protaper Universal y Protaper Next) Posterior al uso clínico.
Mención de responsabilidad etc. Elizabeth Muller Gomez, Nathaly Reina Chavez, Nury Solano Duarte.
260 ## - PUBLICATION, DISTRIBUTION, ETC. (IMPRINT)
Lugar de publicación distribución etc. Bogotá (Colombia);
Nombre del editor distribuidor etc. Institución Universitaria Colegios de Colombia - Unicoc-:
Fecha de publicación distribución etc. 2015.
500 ## - NOTA GENERAL
Nota general Incluye Tabla de Contenido y Referencias.
504 ## - NOTA DE BIBLIOGRAFÍA; ETC.
Nota de bibliografía etc. A. Científico: Juan Carlos Murcia ; A. Metodológico: Angela Suarez Castillo.
505 ## - NOTA DE CONTENIDO CON FORMATO
Nota de contenido con formato
Título Resumen
Objetivo Identificar el grado de deformación y el límite de fractura de los sistemas rotatorios ProTaper Next TM y ProTaper Universal en conductos severamente curvos simulados, posteriores al uso clínico. Materiales y Métodos: Se realizó un estudio experimental in vitro, en el que se comparó la deformación y fractura de los sistemas rotatorios ProTaper Next™ y ProTaper Universal®. Se utilizaron 30 instrumentos del sistema rotatorio ProTaper Next™ 10 de cada referencia (X1, X2 y X3) y 60 instrumentos del sistema rotarios ProTaper Universal®, 10 de cada referencia (SX, S1, S2, F1, F2, F3) para preparación mecánica de cubos de resina estandarizados. Resultados: Instrumentos del sistema PTN funcionaron adecuadamente hasta el uso 10, a diferencia del sistema PTU donde la mayoría de los grupos se fracturo en el uso 5. El número de usos promedio del sistema PTN fue de 8,7 y en el sistema PTU el promedio de uso fue de 4,1. Existen diferencias estadísticamente significativas (P = 0,001) entre los 2 sistemas rotatorios. Conclusión: En el presente estudio se evidencio que las limas PTN presentan un comportamiento superior frente al número de usos, comparado con las del sistema rotatorio PTU
505 ## - NOTA DE CONTENIDO CON FORMATO
Nota de contenido con formato
Título Abstract
The aim of this study was to identify the degree of deformation and fracture limit of Next ProTaper Universal TM and ProTaper rotary systems in severely curved canals clinically simulated after their use. Materials and Methods: An experimental study was conducted in vitro, in which the deformation and fracture of ProTaper ProTaper Universal® Next ™ and Pro Taper rotary systems were compared. 30 instruments ProTaper Next ™ rotary system, 10 of each reference system (X1, X2 and X3) and 60 instruments ProTaper Universal® rotatory system, 10 of each reference (SX, S1, S2, F1, F2, F3) were used for mechanical preparation of standardized resin cubes. Results: PTN Instruments system functioned appropriately until the 10th use, unlikely to PTU system, where the most groups fractured in
the fifth use. The average number of uses for PTN was 8.7 and 4.1 for PTU system, which shows that there are statistically significant differences (P = 0.001) between the two rotating systems. Conclusion: In the present study evidenced that the PTN files have superior performance compared to the number of applications compared with the PTU rotating system
505 ## - NOTA DE CONTENIDO CON FORMATO
Nota de contenido con formato
Título Palabras clave: Protaper next, Protaper universal, deformación, límite de fractura, numero de usos.; - Keywords: Protaper next, Protaper universal, deformation, fracture limit, number of uses.
650 #0 - PUNTO DE ACCESO ADICIONAL DE MATERIA - TÉRMINO DE MATERIA
9 (RLIN) 403
Término de materia o nombre geográfico como elemento inicial Odontología / Endodoncia - Tesis y disertaciones academicas.
700 ## - PUNTO DE ACCESO ADICIONAL - NOMBRE DE PERSONA
9 (RLIN) 4314
Nombre de persona Reina Chavez, Nathaly
700 ## - PUNTO DE ACCESO ADICIONAL - NOMBRE DE PERSONA
9 (RLIN) 4315
Nombre de persona Solano Duarte, Nury
773 ## - ENLACE AL DOCUMENTO FUENTE
Lugar editor y fecha de publicación Bogotá (Colombia), Institución Universitaria Colegios de Colombia - Unicoc-, 2015.
Título Deformación y límite de fractura de dos sistemas rotatorios (Protaper Universal y Protaper Next) Posterior al uso clínico.
Número Internacional Normalizado para Publicaciones Seriadas (ISSN) T.O.E. 0085
942 ## - ENTRADA PARA ELEMENTOS AGREGADOS (KOHA)
Fuente de clasificación o esquema de ordenación en estanterías
Koha [por defecto] tipo de item Trabajo de Grado
Existencias
Estropeado Fecha de adquisición Código de barras Préstamos totales Fuente de clasificación o esquema de ordenación en estanterías Número de ejemplar Tipo de item de Koha Localización permanente Número de inventario Signatura completa Estado de pérdida No para préstamo Fecha última consulta Localización actual Fecha del precio de reemplazo Fecha último préstamo
 2016-02-093672  Ejemplar 1Trabajo de GradoBiblioteca Cali (Dr. Jairo Forero Morales) T.O.E. 0085  2016-02-09Biblioteca Cali (Dr. Jairo Forero Morales)2016-02-09 
 2016-02-093673  Ejemplar 1Trabajo de GradoBiblioteca Cali (Dr. Jairo Forero Morales) TBA T.O.E. 0085  2016-02-09Biblioteca Cali (Dr. Jairo Forero Morales)2016-02-09 
 2015-12-1820152E00851 Ejemplar 1Trabajo de GradoBogotá (Dr. David Ordóñez Rueda) - Campus Norte2 Tesis; 2 Articulos;2CD´sT.O.E. 0085  2016-03-09Bogotá (Dr. David Ordóñez Rueda) - Campus Norte2016-01-262016-03-08

© 2014 UNICOC | Institución Universitaria Colegios de Colombia - UNICOC
Bogotá D.C. Autopista Norte Km. 20. Teléfono:(571)6683535
Cali: Calle 13 Norte No. 3N-13. Teléfono: (572)6608887

Idiomas: 
Con tecnología de Koha