Cambios en el ancho de la encía Queratinizada en pacientes tratados con dos Sistemas de Implantes con relación a la Edad y Biotipo Periodontal - Seguimiento A 2 Años. (Registro nro. 8007)

000 -CABECERA
Campo de control de longitud fija 04796nam a22002657a 4500
003 - IDENTIFICADOR DEL NÚMERO DE CONTROL
Campo de control OSt
005 - FECHA Y HORA DE LA ÚLTIMA TRANSACCIÓN
Campo de control 20180926164838.0
008 - CÓDIGOS DE INFORMACIÓN DE LONGITUD FIJA
Campo de control de longitud fija 151001b xxu||||| |||| 00| 0 eng d
040 ## - FUENTE DE LA CATALOGACIÓN
Centro catalogador de origen Unicoc
Lengua de catalogación spa
Centro transcriptor Unicoc
082 ## - NÚMERO DE LA CLASIFICACIÓN DECIMAL DEWEY
Número de clasificación T.O.Pe. 0067
100 ## - PUNTO DE ACCESO PRINCIPAL - NOMBRE DE PERSONA
9 (RLIN) 3410
Nombre de persona Benavides Varón, Alfonso
245 ## - MENCIÓN DE TÍTULO
Título Cambios en el ancho de la encía Queratinizada en pacientes tratados con dos Sistemas de Implantes con relación a la Edad y Biotipo Periodontal - Seguimiento A 2 Años.
Mención de responsabilidad etc. Alfonso Benavides V.; John Freydell Castro Perdomo; Oscar Javier Salcedo.
260 ## - PUBLICATION, DISTRIBUTION, ETC. (IMPRINT)
Lugar de publicación distribución etc. Bogotá (Colombia);
Nombre del editor distribuidor etc. Postgrado de Periodoncia, Institución Universitaria Colegios de Colombia - UNICOC;
Fecha de publicación distribución etc. 2015.
300 ## - DESCRIPCIÓN FÍSICA
Material anejo 3 CD
500 ## - NOTA GENERAL
Nota general Incluye referencias bibliográficas.
504 ## - NOTA DE BIBLIOGRAFÍA; ETC.
Nota de bibliografía etc. Asesor Científico: Oscar Tocarruncho; Asesor Metodológico: Angela Suarez Castillo, Asesor Estadístico: Jaime Andres Cubides.
505 ## - NOTA DE CONTENIDO CON FORMATO
Título Resumen
Objetivo: comparar los cambios en el ancho de encía queratinizada en caras libres de pacientes: tratados con dos sistemas de implantes (Implante Certain con el nuevo sistema de implantes New Connection), con relación a la edad, biotipo periodontal e influencia del sistema de implantes. Métodos: Estudio observacional descriptivo longitudinal. La muestra estuvo conformada por 41 pacientes. Se tomaron medidas clínicas relacionadas con el ancho de la encía queratinizada y biotipo periodontal. Se realizo el análisis estadístico descriptivo para establecer el ancho de encía queratinizada según el sistema de implantes con relación a la edad, biotipo periodontal, con un periodo de seguimiento a 2 años. Resultados: la tasa de éxito de los implantes fue de 93.3%. El 26.8% (n=29) de los sitios presentaron biotipo delgado y el 73,2%(n=78) biotipo grueso. Se encontraron diferencias significativas entre los grupos : ancho vestibular desde el momento quirúrgico (T1) y dos años después (T5) con un valor p= 0.002; para el ancho lingual p=0.000. No se encontraron diferencias significativas entre los grupos etarios en relación al ancho vestibular (p=0.661). en relación al ancho lingual (P=0.037) si se encontró diferencia en al menos uno de los grupos etàreos. No existen diferencias significativas en el ancho vestibular (p=0.479) y lingual (p=0.362) con relación al sistema de implante. Conclusión: este estudio demostró que no existen diferencias significativas en el ancho de la encía queratinizada con respecto al tipo de implante, edad y biotipo periodontal del paciente; sin embargo, se encontró diferencia significativa cuando se evaluó el ancho de encía queratinizada en los dos puntos de tiempo del momento quirúrgico y dos años después.
505 ## - NOTA DE CONTENIDO CON FORMATO
Título Abstract
Objective: To compare width changes of keratinized free gingival margins in patients treated with two different implant systems in regards to age, periodontal biotype and implant used in a period of two years.Methods: A prospective cohort design was used for this study in which 41 patients participated (n=41). Clinical measurements were taken from the buccal and lingual sites to determine width of keratinized tissue and periodontal biotype. Follow up measurements were taken during and at 2 years period.Results: Implant osseointegration success rate was overall 93.3%. Thin biotype was identified in 26.8% of the sites whereas 73.2% presented a thick biotype. Significant differences were found regarding the buccal width from the time of placement (T1) and two years later (T5) (p=0.002). When comparing the implant systems, at least one of the groups was different in lingual (p=0.037) but none was found regarding buccal width (p=0.661). Overall not significant differences were found between the implant systems regarding the buccal and lingual width (p=0.479 and p=0.362 respectively).Conclusion: This study demonstrates there are no significant differences in width of keratinized tissue regarding age, type of implant and periodontal biotype. However significant differences were observed at time of placement compared with a two year follow up.
505 ## - NOTA DE CONTENIDO CON FORMATO
Título Palabras Clave: encía queratinizada, biotipo periodontal, edad ; -Key words : keratinized mucosa, Dental implant, Tissue Biotype, Age.
650 #0 - PUNTO DE ACCESO ADICIONAL DE MATERIA - TÉRMINO DE MATERIA
9 (RLIN) 383
Término de materia o nombre geográfico como elemento inicial Odontología / Periodoncia - Tesis y Disertaciones Academicas
700 ## - PUNTO DE ACCESO ADICIONAL - NOMBRE DE PERSONA
9 (RLIN) 3714
Nombre de persona Castro Perdomo, John Freydell
700 ## - PUNTO DE ACCESO ADICIONAL - NOMBRE DE PERSONA
9 (RLIN) 3715
Nombre de persona Salcedo, Oscar Javier
773 ## - ENLACE AL DOCUMENTO FUENTE
Lugar editor y fecha de publicación Bogotá, Postgrado de Periodoncia, Institución Universitaria Colegios de Colombia - UNICOC, 2015.
Título Cambios en el ancho de la encía Queratinizada en pacientes tratados con dos Sistemas de Implantes con relación a la Edad y Biotipo Periodontal - Seguimiento A 2 Años.
Número Internacional Normalizado para Publicaciones Seriadas (ISSN) T.O.Pe. 0067
942 ## - ENTRADA PARA ELEMENTOS AGREGADOS (KOHA)
Fuente de clasificación o esquema de ordenación en estanterías
Koha [por defecto] tipo de item Trabajo de Grado
Existencias
Tipo de item de Koha Estado de pérdida No para préstamo Localización permanente Estropeado Fuente de clasificación o esquema de ordenación en estanterías Número de ejemplar Código de barras Fecha del precio de reemplazo Localización actual Fecha última consulta Número de inventario Signatura completa Fecha de adquisición
Trabajo de Grado  Biblioteca Cali (Dr. Jairo Forero Morales)  Ejemplar 137472016-02-09Biblioteca Cali (Dr. Jairo Forero Morales)2016-02-09 T.O.Pe. 00672016-02-09
Trabajo de Grado  Biblioteca Cali (Dr. Jairo Forero Morales)  Ejemplar 137482016-02-09Biblioteca Cali (Dr. Jairo Forero Morales)2016-02-09 TBA T.O.Pe. 00672016-02-09
Trabajo de Grado  Bogotá (Dr. David Ordóñez Rueda) - Campus Norte  Ejemplar 1T.O.Pe.00672015-10-01Bogotá (Dr. David Ordóñez Rueda) - Campus Norte2015-10-012 Tesis, 2 Articulos, 2 CDT.O.Pe. 00672015-10-01

© 2014 UNICOC | Institución Universitaria Colegios de Colombia - UNICOC
Bogotá D.C. Autopista Norte Km. 20. Teléfono:(571)6683535
Cali: Calle 13 Norte No. 3N-13. Teléfono: (572)6608887

Idiomas: 
Con tecnología de Koha