Evaluacion por elementos finitos del esfuerzo y modulo de deformacion en hueso maxilar producido por un mini-implante autoperforante sin nicho previo. (Registro nro. 7645)

000 -LEADER
fixed length control field 03677nam a22002297a 4500
003 - CONTROL NUMBER IDENTIFIER
control field OSt
005 - DATE AND TIME OF LATEST TRANSACTION
control field 20180920151118.0
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION
fixed length control field 150208b xxu||||| |||| 00| 0 eng d
040 ## - CATALOGING SOURCE
Original cataloging agency Unicoc
Language of cataloging spa
Transcribing agency Unicoc
100 ## - MAIN ENTRY--PERSONAL NAME
9 (RLIN) 615
Personal name Addonizio Nardone, Veronica
245 ## - TITLE STATEMENT
Title Evaluacion por elementos finitos del esfuerzo y modulo de deformacion en hueso maxilar producido por un mini-implante autoperforante sin nicho previo.
Statement of responsibility, etc Veronica Addonizio Nardone; Diana Milena Robayo Blanco; Laura Villamarin Avila.
260 ## - PUBLICATION, DISTRIBUTION, ETC. (IMPRINT)
Place of publication, distribution, etc Bogotá (Colombia):
Name of publisher, distributor, etc Colegio Odontológico Colombiano,
Date of publication, distribution, etc 2014.
500 ## - GENERAL NOTE
General note Incluye tabla de contenido y referencias bibliográficas
504 ## - BIBLIOGRAPHY, ETC. NOTE
Bibliography, etc A. Científico: Liliana Jara Lopez;
A. Metodológico: Piedad Malaver;
A. Tecnológico: Breigner Custa.
505 ## - FORMATTED CONTENTS NOTE
Formatted contents note Tesis (Odotólogo) - Colegio Odontológico Colombiano
Title RESUMEN
OBJETIVO: Establecer la distribución de esfuerzos y módulos de deformación producidos en hueso maxilar tras la inserción de un mini-implante auto-perforante sin nicho previo, mediante la simulación matemática por elementos finitos. METODOLOGÍA: Estudio experimental por simulación con elementos finitos de la zona de la tuberosidad del hueso maxilar y de un mini-implante auto-perforante con diámetro de 1.8 mm sin nicho previo por medio del software Ansys 14.0. Se realizaron simulaciones de inserción del mini-implante a diferentes profundidades (1 a 6 mm) y se obtuvieron valores de esfuerzo y deformación elástica tanto del hueso como del mini-implante. RESULTADOS: Se observó una relación inversamente proporcional entre los valores de esfuerzo y deformación elástica y la profundidad de inserción. Los mayores valores se presentaron a 1 mm de profundidad del mini-implante en el hueso, los cuales disminuyeron considerablemente en los 2 mm y presentaron valores estables entre los 3 y 6 mm con tendencia a cero. CONCLUSIÓN: La simulación por elementos finitos determinó que las profundidades de inserción del mini-implante auto-perforante en el hueso maxilar sin nicho previo mayores a 3 mm contribuyen a la obtención de estabilidad primaria del mini-implante.
505 ## - FORMATTED CONTENTS NOTE
Title ABSTRACT
OBJECTIVE: To establish the effort distribution and deformation module caused in maxillary bone following insertion of a self-drilling mini-implant without previous niche, through finite elements system. METHODOLOGY: A descriptive study using finite element system was conducted to model the maxillary tuberosity and a self-drilling mini-implant with 1,8 mm diameter without previous niche using Ansys 14.0 software. Simulations of mini-implant insertion into the maxillar bone at different depths were performed (1 to 6 mm), obtaining effort and elastic deformation values. RESULTS: It was evident an inverse relationship between effort and deformation values and the insertion depth of the mini-implant. Higher values were found at 1 mm depth, which decleaned sharply at 2 mm and became constant between 3 and 6 mm, tending to zero. CONCLUSION: Finite elements simulation established that insertion depths of the self-drilling mini-implan into the maxillary bone without previous niche higher than 3 mm contributes to the primary stability of the mini-implant.
505 ## - FORMATTED CONTENTS NOTE
Title Palabras Clave: Elementos fínitos, esfuerzo, deformación, mini-implante auto perforante, Estabilidad primaria, hueso maxilar ; -Key words: Finite elements, stress, strain, self-drilling mini-implants, jawbone.
650 #0 - SUBJECT ADDED ENTRY--TOPICAL TERM
9 (RLIN) 407
Topical term or geographic name as entry element Odontología / Ortodoncia y ortopedia maxilar - Tesis y disertaciones académicas.
700 ## - ADDED ENTRY--PERSONAL NAME
9 (RLIN) 616
Personal name Robayo Blanco, Diana Milena
700 ## - ADDED ENTRY--PERSONAL NAME
9 (RLIN) 617
Personal name Villamarin Avila, Laura
942 ## - ADDED ENTRY ELEMENTS (KOHA)
Source of classification or shelving scheme
Koha item type Trabajo de Grado
Existencias
Barcode Price effective from Current Location Date last seen Koha item type Copy number Not for loan Date checked out Full call number Permanent Location Source of classification or shelving scheme Total Renewals Date acquired Lost status Damaged status Total Checkouts Inventory number
49372016-02-09Biblioteca Cali (Dr. Jairo Forero Morales)2016-02-09Trabajo de GradoEjemplar 1  T.O.O 0115Biblioteca Cali (Dr. Jairo Forero Morales)  2016-02-09    
49382016-02-09Biblioteca Cali (Dr. Jairo Forero Morales)2016-02-09Trabajo de GradoEjemplar 1  TBA T.O.O 0115Biblioteca Cali (Dr. Jairo Forero Morales)  2016-02-09    
T.O.O. 01152015-02-08Bogotá (Dr. David Ordóñez Rueda) - Campus Norte2019-05-03Trabajo de GradoEjemplar 1 2019-05-03T.O.O. 0115Bogotá (Dr. David Ordóñez Rueda) - Campus Norte 12015-02-08  112 Tesis, 2 Articulos, 3 Cd´s

© 2014 UNICOC | Institución Universitaria Colegios de Colombia - UNICOC
Bogotá D.C. Autopista Norte Km. 20. Teléfono:(571)6683535
Cali: Calle 13 Norte No. 3N-13. Teléfono: (572)6608887

Idiomas: 
Con tecnología de Koha