Cabrera Betancourt, Natalia Giovana

Comparación de traba mecánica y deformación ósea en nichos para mini-implantes en costilla de cerdo con dos tipos de fresa. Natalia Giovana Cabrera Betancourt, Kriss Alejandra Cortes Mosquera. - Bogotá (Colombia); Posgrado de Ortodoncia y Ortopedia Maxilar, Institución Universitaria Colegios de Colombia - UNICOC; 2016.

Incluye Tabla de contenido, referencias bibliográficas y anexos.

Asesora metodológica: Dra. Diana Parra; Asesor estadístico: Dra. Liliana Betancourt López.

RESUMEN
OBJETIVO: Comparar la traba mecánica y deformación ósea en nichos para mini-implantes realizados en costilla de cerdo con fresa helicoidal y anceta. MÉTODO: Este estudio se lleva a cabo en las instalaciones de UNICOC, Universidad Santo Tomas y de la universidad Nacional de Colombia, donde se toman 14 especímenes de costilla de cerdo de 12x2cm aproximadamente, en los cuales se realizan 7 nichos con fresa helicoidal y 7 con anceta donde posteriormente se implanta los tornillos de una longitud de 6mm y diámetro de 1.8mm para ser llevados a una maquina Universal de ensayos donde se realiza la medición de la fuerza de tracción en todas las muestras. Se evaluó la traba mecánica de los mini-implantes en cada nicho según el diseño de la fresa. RESULTADOS: Se realiza la prueba de medias donde se determina que los nichos realizados con fresa helicoidal presentan significancia (p< 0.05) dando mejor traba mecánica; y se determina que el coeficiente de variación es confiable. CONCLUSIÓN: La resistencia a la tracción es mayor en los nichos realizados con fresa helicoidal, presentando una diferencia estadísticamente significativa (p< 0.05), ofreciendo mayor traba mecánica que con los nichos de fresa anceta. ABSTRACT
OBJECTIVE: Compare The Mechanical Lock and osea Deformation in niches for mini- implants performed in pork chop with twist drill and anceta. METHOD: This study was carried out at the premises of UNICOC, University of Santo Tomas and the National University of Colombia, where 14 specimens of pork chop 12x2cm were taken, and were realized 7 niches with twist drill and 7 were performed with anceta. Posteriorly, screws with length 6mm and diameter 1.8mm were implanted for be taken to a universal test machine for measuring the tensile force in all of the samples. It was evaluated the mechanical lock of the mini - implants in each niche according to the design of the drill. RESULTS: It was realized the mean test where it is determined that the niches made with twist drill were significant (p < 0.05) giving better mechanical lock. and it is determined that the coefficient of variation is reliable.CONCLUSION: The tensile strength is greater in the niches made with twist drill , showing a statistically significant difference ( p < 0.05) , offering greater mechanical lock with strawberry anceta niche . Palabras claves: Mini implante; estabilidad primaria; traba mecánica; fresas.; -Key words: Mini implant; primary stability; mechanical locks; drills.


Odontología / Ortodoncia y ortopedia maxilar - Tesis y disertaciones académicas.